Browse INI sections
Dedicated section search, alphabetical index and detailed settings from the catalog.
[Groups] (25 settings)
Group services and settings.
25 settings
DebugEnabled bool
Catalog value : false
Technical description (original English : This makes the Group module very chatty on the console.
Source code : OpenSim/Addons/Groups/GroupsModule.cs:93 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/GroupsModule.cs:117 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/XmlRpcGroupsServicesConnectorModule.cs:198
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
DebugMessagingEnabled
Catalog value : false
Technical description (original English : This makes the Groups Messaging module very chatty on the console. [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]
Source code :
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
DefaultGroupID
Catalog value :
Technical description (original English : Default Groups - add avatar to default group. Only works with V2 groups. Ensure that GroupsService is set in [UserAccountService] section eg. (GroupsService = "OpenSim.Addons.Groups.dll:GroupsService") Set the DefaultGroupID to the UUID of the group Set the DefaultGroupRole to the name of the group role. Defaults to Everyone if not provided or if supplied role is not found. [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]
Source code :
Referenced files:
bin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
DefaultGroupRole
Catalog value :
Technical description (original English : Default Groups - add avatar to default group. Only works with V2 groups. Ensure that GroupsService is set in [UserAccountService] section eg. (GroupsService = "OpenSim.Addons.Groups.dll:GroupsService") Set the DefaultGroupID to the UUID of the group Set the DefaultGroupRole to the name of the group role. Defaults to Everyone if not provided or if supplied role is not found. [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]
Source code :
Referenced files:
bin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
Enabled bool
Catalog value : false
Technical description (original English : Enable groups?. Choices: true false. Default: false. Enables the groups module
Source code : OpenSim/Addons/Groups/GroupsMessagingModule.cs:98 | OpenSim/Addons/Groups/GroupsModule.cs:77 | OpenSim/Addons/Groups/Hypergrid/GroupsServiceHGConnectorModule.cs:76 | OpenSim/Addons/Groups/Local/GroupsServiceLocalConnectorModule.cs:84 | OpenSim/Addons/Groups/Remote/GroupsServiceRemoteConnectorModule.cs:89 | OpenSim/Region/CoreModules/Avatar/Groups/GroupsModule.cs:76 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/GroupsMessagingModule.cs:97 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/GroupsModule.cs:104 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/XmlRpcGroupsServicesConnectorModule.cs:165
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
GroupsCacheTimeout int
Catalog value : 30
Technical description (original English : Groups data is cached for this number of seconds before another request is made to the groups service Set to 0 to disable the cache. Default is 30 seconds
Source code : OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/XmlRpcGroupsServicesConnectorModule.cs:187
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaults
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
GroupsExternalURI string
Catalog value : http://127.0.0.1
Technical description (original English : Inferred from code: Address/URL for groups external uri. string (stored in m_LocalGroupsServiceLocation), read by GroupsServiceHGConnectorModule.
Source code : OpenSim/Addons/Groups/Hypergrid/GroupsServiceHGConnectorModule.cs:84
Referenced files:
bin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
GroupsServerURI string
Catalog value : code: "" / ini: http://yourxmlrpcserver.com/xmlrpc.php
Technical description (original English : Flotsam XmlRpc Service for Groups
Source code : OpenSim/Addons/Groups/Remote/GroupsServiceRemoteConnector.cs:55 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/XmlRpcGroupsServicesConnectorModule.cs:174
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
HomeURI
Catalog value : ${Const|BaseURL}:${Const|PublicPort}
Technical description (original English : What's the home address of this world?. Depends on: ServicesConnectorModule:Groups HG Service Connector. http://mygridserver.com:9000 or http://mygridserver.com:8002 If you have this set in [Hypergrid] section of GridCommon.ini or StandaloneCommon.ini files in config-include folder, leave it commented [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]
Source code :
Referenced files:
bin/OpenSim.ini.example— Template / example / testbin/Robust.HG.ini.example— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
LevelGroupCreate int
Catalog value : 0
Technical description (original English : Minimum user level required to create groups
Source code : OpenSim/Addons/Groups/GroupsModule.cs:94 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/GroupsModule.cs:118
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
LocalService string
Catalog value : local
Technical description (original English : Is the group service in this process or elsewhere?. Choices: local remote. Depends on: ServicesConnectorModule:Groups HG Service Connector. Default: local. Used for V2 in HG only. If standalone, set this to local; if grided sim, set this to remote
Source code : OpenSim/Addons/Groups/Hypergrid/GroupsServiceHGConnectorModule.cs:83
Referenced files:
bin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
MaxAgentGroups int
Catalog value : 42
Technical description (original English : Sets the maximum number of groups an agent may join
Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:195
Referenced files:
bin/Robust.HG.ini.example— Template / example / testbin/Robust.ini.example— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
MessageOnlineUsersOnly bool
Catalog value : false
Technical description (original English : Experimental option to only message cached online users rather than all users Should make large group with few online members messaging faster, at the expense of more calls to ROBUST presence service (Flotsam groups only; in V2 this is always on)
Source code : OpenSim/Addons/Groups/GroupsMessagingModule.cs:110 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/GroupsMessagingModule.cs:111
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
MessagingEnabled bool
Catalog value : true
Technical description (original English : Specify which messaging module to use for groups messaging and if it's enabled
Source code : OpenSim/Addons/Groups/GroupsMessagingModule.cs:105 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/GroupsMessagingModule.cs:104
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
MessagingModule string
Catalog value : code: "" / ini: GroupsMessagingModule, Groups Messaging Module V2
Technical description (original English : Specify which messaging module to use for groups messaging and if it's enabled
Source code : OpenSim/Addons/Groups/GroupsMessagingModule.cs:99 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/GroupsMessagingModule.cs:98
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
Module string
Catalog value : Default
Technical description (original English : This is the current groups stub in Region.CoreModules.Avatar.Groups. All the other settings below only really apply to the Flotsam GroupsModule
Source code : OpenSim/Addons/Groups/GroupsModule.cs:83 | OpenSim/Region/CoreModules/Avatar/Groups/GroupsModule.cs:83 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/GroupsModule.cs:108
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
NoticesEnabled bool
Catalog value : true
Technical description (original English : Enable Group Notices
Source code : OpenSim/Addons/Groups/GroupsModule.cs:92 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/GroupsModule.cs:116
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
OfflineIMService string
Catalog value : code: "" / ini: OpenSim.Addons.OfflineIM.dll:OfflineIMService
Technical description (original English : for the HG Groups service
Source code : OpenSim/Addons/Groups/Hypergrid/HGGroupsServiceRobustConnector.cs:78
Referenced files:
bin/Robust.HG.ini.example— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
SecretKey string
Catalog value : ***
Technical description (original English : Secret key between sim and remote group service. Depends on: ServicesConnectorModule:Groups Remote Service Connector. Default: "". Used for V2 in Remote only.
Source code : OpenSim/Addons/Groups/Remote/GroupsServiceRobustConnector.cs:65
Referenced files:
bin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
ServicesConnectorModule string
Catalog value : code: "", XmlRpcGroupsServicesConnector / ini: XmlRpcGroupsServicesConnector
Technical description (original English : Flotsam XmlRpc Service for Groups
Source code : OpenSim/Addons/Groups/Hypergrid/GroupsServiceHGConnectorModule.cs:77 | OpenSim/Addons/Groups/Local/GroupsServiceLocalConnectorModule.cs:85 | OpenSim/Addons/Groups/Remote/GroupsServiceRemoteConnectorModule.cs:90 | OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/XmlRpcGroupsServicesConnectorModule.cs:166
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
StorageProvider
Catalog value : OpenSim.Data.MySQL.dll
Technical description (original English : The DLL that provides the storage for V2. Choices: OpenSim.Data.MySQL.dll. Depends on: Module:Groups Module V2. [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]
Source code :
Referenced files:
bin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
UserAccountService string
Catalog value : code: "" / ini: OpenSim.Services.UserAccountService.dll:UserAccountService
Technical description (original English : for the HG Groups service
Source code : OpenSim/Addons/Groups/Hypergrid/HGGroupsServiceRobustConnector.cs:88
Referenced files:
bin/Robust.HG.ini.example— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
XmlRpcDisableKeepAlive bool
Catalog value : true
Technical description (original English : Disables HTTP Keep-Alive for XmlRpcGroupsServicesConnector HTTP Requests, only set to false if you absolutely sure regions and groups server supports it.
Source code : OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/XmlRpcGroupsServicesConnectorModule.cs:182
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaults
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
XmlRpcServiceReadKey string
Catalog value : ***
Technical description (original English : XmlRpc Security settings. These must match those set on your backend groups service if the service is using these keys
Source code : OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/XmlRpcGroupsServicesConnectorModule.cs:184
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
XmlRpcServiceWriteKey string
Catalog value : ***
Technical description (original English : XmlRpc Security settings. These must match those set on your backend groups service if the service is using these keys
Source code : OpenSim/Region/OptionalModules/Avatar/XmlRpcGroups/XmlRpcGroupsServicesConnectorModule.cs:185
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.