OpenSimulator · EN

Browse INI sections

Dedicated section search, alphabetical index and detailed settings from the catalog.

This index only includes entries with an explicit INI-file reference in the catalog. Optional modules and example templates may still appear: always verify the source file before adding settings.

← Back to all sections

[LoginService] (42 settings)

Avatar login service behavior.

42 settings

AllowedClients string

Catalog value : ""

Technical description (original English : Regular expressions for controlling which client versions are accepted/denied. An empty string means nothing is checked. Example 1: allow only these 3 types of clients (any version of them) AllowedClients = "Imprudence|Hippo|Second Life" Example 2: allow all clients except these DeniedClients = "Twisted|Crawler|Cryolife|FuckLife|StreetLife|GreenLife|AntiLife|KORE-Phaze|Synlyfe|Purple Second Life|SecondLi |Emerald" Note that these are regular expressions, so every character counts. Also note that this is very weak security and should not be trusted as a reliable means for keeping bad clients out; modified clients can fake their identifiers. [Also looked up in: AccessControl (later sections override earlier).]

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:138

Template / example / test

Referenced files:

  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

AllowLoginFallbackToAnyRegion bool

Catalog value : code: true / ini: false, true

Technical description (original English : If the region requested at login is not found and there are no default or fallback regions online or defined in section [GridService], try to send user to any region online this similar to legacy (was disabled on 0.9.2.0) you should set this to false and define regions with Default and possible Fallback flags With this option set to true, users maybe sent to regions they where not supposed to be, or even know about

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:135

Template / example / test

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

AllowRemoteSetLoginLevel bool

Catalog value : false

Technical description (original English : Inferred from code: If true, allow remote set login level. bool (stored in m_AllowRemoteSetLoginLevel), read by LLLoginService.

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:122

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

AuthenticationService string

Catalog value : code: "" / ini: OpenSim.Services.AuthenticationService.dll:PasswordAuthenticationService

Technical description (original English : for the service

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:111

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/Standalone.ini — Included configuration
  • bin/config-include/StandaloneHypergrid.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

AvatarPicker string

Catalog value : code: "" / ini: ${Const|BaseURL}/avatars

Technical description (original English : For V3 avatar picker (( work in progress ))

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:133

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

AvatarService string

Catalog value : code: "" / ini: OpenSim.Services.AvatarService.dll:AvatarService

Technical description (original English : for the service

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:117

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/Standalone.ini — Included configuration
  • bin/config-include/StandaloneHypergrid.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

ClassifiedFee string

Catalog value : code: "" / ini: 0

Technical description (original English : Set minimum fee to publish classified

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:131

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

Currency string

Catalog value : ""

Technical description (original English : Ask co-operative viewers to use a different currency name

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:130

Template / example / testOther fileROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Gloebit.ini — Other file
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

DeniedClients string

Catalog value : ""

Technical description (original English : Regular expressions for controlling which client versions are accepted/denied. An empty string means nothing is checked. Example 1: allow only these 3 types of clients (any version of them) AllowedClients = "Imprudence|Hippo|Second Life" Example 2: allow all clients except these DeniedClients = "Twisted|Crawler|Cryolife|FuckLife|StreetLife|GreenLife|AntiLife|KORE-Phaze|Synlyfe|Purple Second Life|SecondLi |Emerald" Note that these are regular expressions, so every character counts. Also note that this is very weak security and should not be trusted as a reliable means for keeping bad clients out; modified clients can fake their identifiers. [Also looked up in: AccessControl (later sections override earlier).]

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:152

Template / example / test

Referenced files:

  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

DeniedID0s string

Catalog value : ""

Technical description (original English : Keep spaces between each mac, do not use vertical bars e.g. | to separate the mac strings. Attempt to login or hypergrid in to the grid, teleport should timeout and login should fail. [Also looked up in: AccessControl (later sections override earlier).]

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:167

ROBUSTTemplate / example / test

Referenced files:

  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

DeniedMacs string

Catalog value : code: "" / ini: YOURLONGMACTRSING ANOTHERMAC

Technical description (original English : Allow banning via hashed MAC must be set in both [GatekeeperService] and [LoginService] [Also looked up in: AccessControl (later sections override earlier).]

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:166

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

DestinationGuide string

Catalog value : code: "" / ini: ${Const|BaseURL}/guide

Technical description (original English : For V3 destination guide

Source code : OpenSim/Services/GridService/GridService.cs:217 | OpenSim/Services/LLLoginService/LLLoginService.cs:132

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

DestinationGuideURI

Catalog value :

Technical description (original English : For V3 destination guide [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

ROBUSTTemplate / example / test

Referenced files:

  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

DOSAllowXForwardedForHeader

Catalog value :

Technical description (original English : Basic Login Service Dos Protection Tweaks Some Grids/Users use a transparent proxy that makes use of the X-Forwarded-For HTTP Header, If you do, set this to true If you set this to true and you don't have a transparent proxy, it may allow attackers to put random things in the X-Forwarded-For header to get around this basic DOS protection. [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

ROBUSTTemplate / example / test

Referenced files:

  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

DOSForgiveClientAfterMS int

Catalog value : 120000

Technical description (original English : The amount of time that a specific endpoint is blocked. Default 2 minutes.

Source code : OpenSim/Server/Handlers/Login/LLLoginServiceInConnector.cs:96

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

DOSMaxRequestsInTimeFrame int

Catalog value : 5

Technical description (original English : The amount of requests in the above timeframe from the same endpoint that triggers protection

Source code : OpenSim/Server/Handlers/Login/LLLoginServiceInConnector.cs:94

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

DOSRequestTimeFrameMS int

Catalog value : 10000

Technical description (original English : The protector adds up requests during this rolling period of time, default 10 seconds

Source code : OpenSim/Server/Handlers/Login/LLLoginServiceInConnector.cs:93

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

DSTZone string

Catalog value : America/Los_Angeles;Pacific Standard Time

Technical description (original English : Override Daylight Saving Time rules. Choices: * none local. Default: "America/Los_Angeles;Pacific Standard Time". Viewers do not receive timezone information from the server - almost all (?) default to Pacific Standard Time However, they do rely on the server to tell them whether it's Daylight Saving Time or not. Hence, calculating DST based on a different timezone can result in a misleading viewer display and inconsistencies between grids. By default, this setting uses various timezone names to calculate DST with regards to the viewer's standard PST. Options are "none" no DST "local" use the server's only timezone to calculate DST. This is previous OpenSimulator behaviour. "America/Los_Angeles;Pacific Standard Time" use these timezone names to look up Daylight savings. 'America/Los_Angeles' is used on Linux/Mac systems whilst 'Pacific Standard Time' is used on Windows

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:189

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/Standalone.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

FriendsService string

Catalog value : code: "" / ini: OpenSim.Services.FriendsService.dll:FriendsService

Technical description (original English : for the service

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:116

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/Standalone.ini — Included configuration
  • bin/config-include/StandaloneHypergrid.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

GatekeeperURI string

Catalog value : code: "" / ini: ${Const|BaseURL}:${Const|PublicPort}

Technical description (original English : Defaults for the users, if none is specified in the useraccounts table entry (ServiceURLs) If you have GatekeeperURI set under [Hypergrid], no need to set it here, leave it commented [Also looked up in: Hypergrid, Startup (later sections override earlier).]

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:124

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

GridService string

Catalog value : code: "" / ini: OpenSim.Services.GridService.dll:GridService

Technical description (original English : for the service

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:113

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/Standalone.ini — Included configuration
  • bin/config-include/StandaloneHypergrid.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

GridUserService string

Catalog value : code: "" / ini: OpenSim.Services.UserAccountService.dll:GridUserService

Technical description (original English : for the service

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:109

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/Standalone.ini — Included configuration
  • bin/config-include/StandaloneHypergrid.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

HasProxy

Catalog value : false

Technical description (original English : If you run this login server behind a proxy, set this to true [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

HGInventoryServicePlugin string

Catalog value : code: "" / ini: HGInventoryService@OpenSim.Services.HypergridService.dll:HGSuitcaseInventoryService

Technical description (original English : This inventory service will be used to initialize the user's inventory

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:239

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/config-include/StandaloneHypergrid.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

InventoryService string

Catalog value : code: "" / ini: OpenSim.Services.InventoryService.dll:XInventoryService

Technical description (original English : for the service

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:112

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/Standalone.ini — Included configuration
  • bin/config-include/StandaloneHypergrid.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

LibraryService string

Catalog value : code: "" / ini: OpenSim.Services.InventoryService.dll:LibraryService

Technical description (original English : for the service

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:115

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

LocalServiceModule string

Catalog value : code: "" / ini: OpenSim.Services.LLLoginService.dll:LLLoginService

Technical description (original English : for the server connector

Source code : OpenSim/Server/Handlers/Login/LLLoginServiceInConnector.cs:86

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/Standalone.ini — Included configuration
  • bin/config-include/StandaloneHypergrid.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

MapTileURL string

Catalog value : code: "" / ini: ${Const|BaseURL}:${Const|PublicPort}/map/

Technical description (original English : For V2 map [Also looked up in: HGWorldMap, SimulatorFeatures (later sections override earlier).]

Source code : OpenSim/Region/CoreModules/World/WorldMap/HGWorldMapModule.cs:66 | OpenSim/Services/GridService/GridService.cs:207 | OpenSim/Services/LLLoginService/LLLoginService.cs:126

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

MinLoginLevel int

Catalog value : 0

Technical description (original English : The minimum user level required for a user to be able to login. 0 by default If you disable a particular user's account then you can set their login level below this number. You can also change this level from the console though these changes will not be persisted.

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:123 | OpenSim/Services/LLLoginService/LLLoginService.cs:1163

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

PresenceService string

Catalog value : code: "" / ini: OpenSim.Services.PresenceService.dll:PresenceService

Technical description (original English : for the service

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:114

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/Standalone.ini — Included configuration
  • bin/config-include/StandaloneHypergrid.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

SearchURL string

Catalog value : code: "" / ini: ${Const|BaseURL}:${Const|PublicPort}/, ${Const|BaseURL}:${Const|PublicPort}

Technical description (original English : Url to search service

Source code : OpenSim/Services/GridService/GridService.cs:203 | OpenSim/Services/LLLoginService/LLLoginService.cs:129

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/config-include/Proto/Region/OpenSim.ini — Template / example / test
  • bin/config-include/Proto/Robust/OpenSim.ini — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

SimulationService string

Catalog value : code: "" / ini: OpenSim.Services.Connectors.dll:SimulationServiceConnector

Technical description (original English : for the service

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:118

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

SRV_AssetServerURI

Catalog value : ${Const|BaseURL}:${Const|PublicPort}

Technical description (original English : Defaults for the users, if none is specified in the useraccounts table entry (ServiceURLs) If you have GatekeeperURI set under [Hypergrid], no need to set it here, leave it commented [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

SRV_FriendsServerURI

Catalog value : ${Const|BaseURL}:${Const|PublicPort}

Technical description (original English : Defaults for the users, if none is specified in the useraccounts table entry (ServiceURLs) If you have GatekeeperURI set under [Hypergrid], no need to set it here, leave it commented [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

SRV_GroupsServerURI

Catalog value : ${Const|BaseURL}:${Const|PublicPort}

Technical description (original English : Defaults for the users, if none is specified in the useraccounts table entry (ServiceURLs) If you have GatekeeperURI set under [Hypergrid], no need to set it here, leave it commented [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

SRV_HomeURI string

Catalog value : ini: ${Const|BaseURL}:${Const|PublicPort}, ${Hypergrid|HomeURI} (code: tmp)

Technical description (original English : Defaults for the users, if none is specified in the useraccounts table entry (ServiceURLs) If you have GatekeeperURI set under [Hypergrid], no need to set it here, leave it commented

Source code : OpenSim/Server/Handlers/Grid/GridInfoHandlers.cs:154

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

SRV_IMServerURI

Catalog value : ${Const|BaseURL}:${Const|PublicPort}

Technical description (original English : Defaults for the users, if none is specified in the useraccounts table entry (ServiceURLs) If you have GatekeeperURI set under [Hypergrid], no need to set it here, leave it commented [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

SRV_InventoryServerURI

Catalog value : ${Const|BaseURL}:${Const|PublicPort}

Technical description (original English : Defaults for the users, if none is specified in the useraccounts table entry (ServiceURLs) If you have GatekeeperURI set under [Hypergrid], no need to set it here, leave it commented [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

SRV_ProfileServerURI

Catalog value : ${Const|BaseURL}:${Const|PublicPort}

Technical description (original English : Defaults for the users, if none is specified in the useraccounts table entry (ServiceURLs) If you have GatekeeperURI set under [Hypergrid], no need to set it here, leave it commented [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

UserAccountService string

Catalog value : code: "" / ini: OpenSim.Services.UserAccountService.dll:UserAccountService

Technical description (original English : for the service

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:108

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/Standalone.ini — Included configuration
  • bin/config-include/StandaloneHypergrid.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

UserAgentService string

Catalog value : code: "" / ini: OpenSim.Services.HypergridService.dll:UserAgentService

Technical description (original English : for hypergrid

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:110

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/config-include/StandaloneHypergrid.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

WelcomeMessage string

Catalog value : code: Welcome to OpenSim! / ini: Welcome, Avatar!

Technical description (original English : Inferred from code: Sets welcome message. string (stored in m_WelcomeMessage), read by LLLoginService.

Source code : OpenSim/Services/LLLoginService/LLLoginService.cs:120 | OpenSim/Services/LLLoginService/LLLoginService.cs:185

Template / example / testIncluded configurationROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/config-include/Standalone.ini — Included configuration
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.