Browse INI sections
Dedicated section search, alphabetical index and detailed settings from the catalog.
[RemoteAdmin] (14 settings)
The settings below are listed in the catalog. Availability depends on OpenSimulator version and installed modules.
14 settings
access_ip_addresses string
Catalog value : code: "" / ini: 0.0.0.0, 0.0.0.0 ...
Technical description (original English : List the IP addresses allowed to call RemoteAdmin If access_ip_addresses isn't set, then all IP addresses can access RemoteAdmin.
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:115
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
access_password string
Catalog value : ***
Technical description (original English : This password is required to make any XMLRPC call (should be set as the "password" parameter)
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:112 | OpenSim/Region/OptionalModules/Avatar/Chat/IRCBridgeModule.cs:88
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
bind_ip_address string
Catalog value : 0.0.0.0
Technical description (original English : Set this to the ip address that you want the admin server to bind to
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:130
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaults
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
copy_folders bool
Catalog value : false
Technical description (original English : update appearance copies inventory items and wearables of default avatars. if this value is false (default), just worn assets are copied to the Clothes folder; if true, all Clothes and Bodyparts subfolders are copied. the receiver will wear the same items the default avatar did wear.
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:2881
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
create_region_enable_voice bool
Catalog value : false
Technical description (original English : set this variable to true if you want the create_region XmlRpc call to unconditionally enable voice on all parcels for a newly created region [default: false]
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:731
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
create_region_public bool
Catalog value : code: true / ini: false
Technical description (original English : set this variable to false if you want the create_region XmlRpc call to create all regions as private per default (can be overridden in the XmlRpc call) [default: true]
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:732
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
default_appearance string
Catalog value : default_appearance.xml
Technical description (original English : path to default appearance XML file that specifies the look of the default avatars
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:3232
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
default_female string
Catalog value : code: Default Female, Default Default / ini: Default Female
Technical description (original English : specify the default appearance for an avatar created through the remote admin interface This will only take effect is the file specified by the default_appearance setting below exists
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:2794 | OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:2795
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
default_male string
Catalog value : Default Male
Technical description (original English : specify the default appearance for an avatar created through the remote admin interface This will only take effect is the file specified by the default_appearance setting below exists
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:2793
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
enabled bool
Catalog value : false
Technical description (original English : Enable the remote admin interface?. Choices: true false. Default: false.
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:104
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
enabled_methods string
Catalog value : all
Technical description (original English : enable only those methods you deem to be appropriate using a | delimited whitelist for example, enabled_methods = admin_broadcast|admin_region_query|admin_save_oar|admin_save_xml if this parameter is not specified but enabled = true, all methods will be available
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:182
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
port int
Catalog value : 0
Technical description (original English : Set this to a nonzero value to have remote admin use a different port
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:113
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaultsbin/OpenSim.ini.example— Template / example / testbin/config-include/Proto/OsGrid/OpenSim.ini— Template / example / testbin/config-include/Proto/Region/OpenSim.ini— Template / example / testbin/config-include/Proto/Robust/OpenSim.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
region_file_template string
Catalog value : {0}x{1}-{2}.ini
Technical description (original English : the create_region XmlRpc call uses region_file_template to generate the file name of newly create regions (if they are created persistent). the parameter available are: {0} - X location {1} - Y location {2} - region UUID {3} - region port {4} - region name with " ", ":", "/" mapped to "_"
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:837
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaults
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
region_limit int
Catalog value : 0
Technical description (original English : we can limit the number of regions that XmlRpcCreateRegion will allow by setting this to a positive, non-0 number: as long as the number of regions is below region_limits, XmlRpcCreateRegion will succeed. setting region_limit to 0 disables the check. default is 0
Source code : OpenSim/ApplicationPlugins/RemoteController/RemoteAdminPlugin.cs:730
Referenced files:
bin/OpenSimDefaults.ini— Shipped defaults
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.