Browse INI sections
Dedicated section search, alphabetical index and detailed settings from the catalog.
[UserProfilesService] (6 settings)
The settings below are listed in the catalog. Availability depends on OpenSimulator version and installed modules.
6 settings
AuthenticationServiceModule
Catalog value : OpenSim.Services.AuthenticationService.dll:PasswordAuthenticationService
Technical description (original English : Configure this for separate profiles database ConnectionString = "Data Source=localhost;Database=opensim;User ID=opensim;Password=*****;Old Guids=true;" Realm = UserProfiles [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]
Source code :
Referenced files:
bin/Robust.HG.ini.example— Template / example / testbin/Robust.ini.example— Template / example / testbin/config-include/StandaloneCommon.ini.example— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / testbin/Robust.Tests.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
ConnectionString
Catalog value : Data Source=localhost;Database=opensim;User ID=opensim;Password=***;Old Guids=true;
Technical description (original English : Configure this for separate databse [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]
Source code :
Referenced files:
bin/config-include/StandaloneCommon.ini.example— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
Enabled bool
Catalog value : false
Technical description (original English : To use, set Enabled to true then configure for your site...
Source code : OpenSim/Region/CoreModules/ServiceConnectorsIn/UserProfiles/LocalUserProfilesServiceConnector.cs:106 | OpenSim/Server/Handlers/Profiles/UserProfilesConnector.cs:72
Referenced files:
bin/Robust.HG.ini.example— Template / example / testbin/Robust.ini.example— Template / example / testbin/config-include/StandaloneCommon.ini.example— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / testbin/Robust.Tests.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
LocalServiceModule string
Catalog value : code: "" / ini: OpenSim.Services.UserProfilesService.dll:UserProfilesService
Technical description (original English : To use, set Enabled to true then configure for your site...
Source code : OpenSim/Region/CoreModules/ServiceConnectorsIn/UserProfiles/LocalUserProfilesServiceConnector.cs:114 | OpenSim/Server/Handlers/Profiles/UserProfilesConnector.cs:82
Referenced files:
bin/Robust.HG.ini.example— Template / example / testbin/Robust.ini.example— Template / example / testbin/config-include/StandaloneCommon.ini.example— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / testbin/Robust.Tests.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
Realm
Catalog value : UserProfiles
Technical description (original English : Configure this for separate databse [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]
Source code :
Referenced files:
bin/config-include/StandaloneCommon.ini.example— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.
UserAccountService
Catalog value : OpenSim.Services.UserAccountService.dll:UserAccountService
Technical description (original English : Configure this for separate profiles database ConnectionString = "Data Source=localhost;Database=opensim;User ID=opensim;Password=*****;Old Guids=true;" Realm = UserProfiles [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]
Source code :
Referenced files:
bin/Robust.HG.ini.example— Template / example / testbin/Robust.ini.example— Template / example / testbin/config-include/StandaloneCommon.ini.example— Template / example / testbin/Robust.HG.ini— ROBUSTbin/Robust.HG.ini.proto— Template / example / testbin/Robust.Tests.ini— Template / example / test
This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.