OpenSimulator · EN

Browse INI sections

Dedicated section search, alphabetical index and detailed settings from the catalog.

This index only includes entries with an explicit INI-file reference in the catalog. Optional modules and example templates may still appear: always verify the source file before adding settings.

← Back to all sections

[UserProfilesService] (6 settings)

The settings below are listed in the catalog. Availability depends on OpenSimulator version and installed modules.

6 settings

AuthenticationServiceModule

Catalog value : OpenSim.Services.AuthenticationService.dll:PasswordAuthenticationService

Technical description (original English : Configure this for separate profiles database ConnectionString = "Data Source=localhost;Database=opensim;User ID=opensim;Password=*****;Old Guids=true;" Realm = UserProfiles [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

ConnectionString

Catalog value : Data Source=localhost;Database=opensim;User ID=opensim;Password=***;Old Guids=true;

Technical description (original English : Configure this for separate databse [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

Template / example / test

Referenced files:

  • bin/config-include/StandaloneCommon.ini.example — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

Enabled bool

Catalog value : false

Technical description (original English : To use, set Enabled to true then configure for your site...

Source code : OpenSim/Region/CoreModules/ServiceConnectorsIn/UserProfiles/LocalUserProfilesServiceConnector.cs:106 | OpenSim/Server/Handlers/Profiles/UserProfilesConnector.cs:72

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

LocalServiceModule string

Catalog value : code: "" / ini: OpenSim.Services.UserProfilesService.dll:UserProfilesService

Technical description (original English : To use, set Enabled to true then configure for your site...

Source code : OpenSim/Region/CoreModules/ServiceConnectorsIn/UserProfiles/LocalUserProfilesServiceConnector.cs:114 | OpenSim/Server/Handlers/Profiles/UserProfilesConnector.cs:82

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

Realm

Catalog value : UserProfiles

Technical description (original English : Configure this for separate databse [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

Template / example / test

Referenced files:

  • bin/config-include/StandaloneCommon.ini.example — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.

UserAccountService

Catalog value : OpenSim.Services.UserAccountService.dll:UserAccountService

Technical description (original English : Configure this for separate profiles database ConnectionString = "Data Source=localhost;Database=opensim;User ID=opensim;Password=*****;Old Guids=true;" Realm = UserProfiles [Appears only in INI files; no literal read found in C# (may be read via a dynamic key, by another program, or obsolete).]

Source code :

Template / example / testROBUST

Referenced files:

  • bin/Robust.HG.ini.example — Template / example / test
  • bin/Robust.ini.example — Template / example / test
  • bin/config-include/StandaloneCommon.ini.example — Template / example / test
  • bin/Robust.HG.ini — ROBUST
  • bin/Robust.HG.ini.proto — Template / example / test
  • bin/Robust.Tests.ini — Template / example / test

This is provenance, not active configuration. Edit only files loaded by your architecture. On a simulator check effective values with config show. .example files must be copied and customized before use.